Radiation Protection Detection & Measurement Others
ILJINRAD

[ILJINRAD's business scope]
Manufacturing and development of radiation (radioactivity) measurement equipment and direct-reading dosimeters (ADR)
2KOLAS-accredited calibration services for radiation measurement equipment
Manufacturing of thermoluminescent dosimeter (TLD) elements and dose reading services
Radiation safety management outsourcing services
Radiation safety management for public institutions, including nuclear power plants
Construction of high-level gamma irradiation facilities
National R&D projects

[ILJINRAD's core technical capabilities]
Licensing of RI/RG usage, sales, and production facilities
Design approval of radiation equipment and inspection/supervision of usage facilities
Establishment of calibration systems for gamma irradiation facilities
Design, construction, and supervision (on-site calibration) of high-level gamma irradiation facilities
Radiation facility construction, including radiation irradiation rooms and shielding door installation

Radiation Instrumentation¡¤Measurement and Radiation Protection¡¤Safety

Products

Radiation Protection Survey Meter
(Model : FORRAD YK-100) Image 1
Radiation Protection Survey Meter
(Model : FORRAD YK-100) Image 2
Radiation Protection Survey Meter
(Model : FORRAD YK-100) Image 3
Radiation Protection Survey Meter
(Model : FORRAD YK-100) Image 4

Radiation Protection Survey Meter
(Model : FORRAD YK-100)

Radiation Instrumentation¡¤Measurement, and Radiation Protection¡¤Safety

FCC RoHS DoC Environmental Certifications KS C IEC 60846-1(in progress)
Size 158 x 75 x 65 mm
Weight 325kg HS Code -
Key Specifications ¡Û Detection targets : Gamma, X-ray, ¥á, ¥â ¡Û Detector type : Pancake-type GM ¡Û Dose rate : BkG ~ 2mSv/h ¡Û Sensitivity(Cs-137) : 10uSv/h ¡Û Energy dependence : 60keV ~ 1.2MeV ¡Û Angular dependence : ¡¾75¡Æ(frontal) ¡Û Unit : Sv/h, R/h, CPS, CPM ¡Û Display : Graphic LCD 128 x 64 ¡Û Data storage: 50 ea ¡Û Battery : AA size x 2ea (120-hour run-time with background) ¡Û Compliant with IEC-61000-4-2 / 4-3 / 4-8 ¡Û IP65 according to 60529 ¡Û EMC 50081-1, EN 61000-6-2
Applicatioon Areas ¡Û Nuclear Power Sector - Operators of nuclear power plants and research reactors, and manufacturers of nuclear fuel materials, etc. - Monitoring of radioactive waste disposal facilities, waste storage sites, etc. ¡Û Non-Power Sector - Nuclear and radiation-related research institutes, hospital nuclear medicine departments, etc. - Institutions utilizing radiation and RI, universities, research institutes, military-affiliated organizations, etc. - Non-destructive testing(NDT) agencies, Organizations involved in the use, licensing, and registration of RI/RG, etc. - Radiation detector development organizations, etc.

¡Û Design optimization for radiation instrument response - Evaluation of radiation response variations, derivation of response functions, etc. ¡Û Measurement of radiation and radioactivity ¡Û Performance testing of radiation protection instruments(KS C IEC 60846-1) in progress - Response variations regarding energy and angle of incidence, dose rate linearity, statistical fluctuations, dose rate dependence, overload, response stability, and environmental factors (ambient temperature, relative humidity), etc. ¡Û Holds product patents (2 items) ¡Û Equipped with optimized algorithms ¡Û Utilized for radiation/radioactivity measurement and monitoring

Certifications